Marginal consistency checks#
Before retrieving, it is worth asking whether the trace is even consistent with the independently measured spectrum. The frequency marginal \(M(\omega)=\int T(\omega,\tau)\,\mathrm d\tau\) can be predicted (or rigorously bounded) from the fundamental spectrum \(S(\omega)\), so comparing the two flags calibration, spectral-response, scatter and detector-nonlinearity problems that a retrieval would otherwise absorb. The physics is in FROG trace marginals as consistency checks; this page is the recipe.
The identities assume a thin, local interaction and complete delay support; a dispersive slab, smearing or a finite collection aperture also reshape the marginal. For SHG through a crystal, the prediction can include the crystal’s phase matching (see Through an SHG crystal below).
Predict a marginal from a spectrum#
croak.marginal_checks.predicted_marginal() takes a uniform absolute
angular-frequency axis and a nonnegative spectral intensity, and returns a
MarginalPrediction carrying the predicted marginal
and its centroid/width anchors:
import numpy as np
import croak
from croak import marginal_checks as mc
omega0 = float(croak.maths.wlfreq(800e-9)) # ~800 nm carrier (rad/s)
g = croak.Grid(1024, dt=0.4e-15)
omega = g.omega + omega0 # absolute frequency axis
S = np.exp(-0.5 * ((omega - omega0) / (0.03 * omega0)) ** 2) # fundamental spectrum
pred = mc.predicted_marginal(omega, S, "shg")
pred.centroid # 2·ω̄_S (rad/s) — hard for SHG
pred.rms_width # √2·σ_S — hard for SHG
pred.centroid_is_hard, pred.width_is_hard # (True, True)
The geometry sets which anchors are rigorous:
|
centroid |
width |
|
|---|---|---|---|
|
|
|
|
|
|
TL |
|
|
|
|
|
Use predicted_centroid() if you only need the centroid
anchor, and spectral_autoconvolution() for the raw
\(S*S\) shape.
Compare with a measured marginal#
Compute the measured marginal and its moments on a common, calibrated axis (work in angular frequency — convert a wavelength-density marginal to an \(\omega\)-density with the \(\times\lambda^2\) Jacobian first):
marg = trace.sum(axis=1) # measured marginal (delay is axis 1)
omega_t = croak.maths.wlfreq(lam) # the trace's wavelength axis -> rad/s
weights = marg * lam**2 # λ-density -> ω-density
c_meas = mc.centroid(omega_t, weights)
sigma_meas = mc.rms_width(omega_t, weights)
print("centroid error:", c_meas - pred.centroid) # the calibration QC metric
print("width OK:", sigma_meas > pred.sigma_spectrum) # rigorous lower bound
Interpreting a mismatch:
SHG — a centroid, width or shape mismatch means the trace and spectrum are inconsistent: calibration, spectral response, scatter or detector nonlinearity.
PG / TG — the centroid is still a hard calibration check; a width below
σ_Smeans spectral clipping or detector roll-off. The TL widthσ_TLis a soft reference: phase structure can exceed it.SD — only the width lower bound is rigorous; the centroid holds at TL or for a temporally symmetric pulse.
Restrict the moments and the shape comparison to a spectral trust region so out-of-band detector noise — amplified by any efficiency tilt — cannot dominate.
Fit the third-order efficiency exponent#
A TG/PG detector’s third-order generation/collection efficiency tilts the
marginal by \((\lambda/\mu\mathrm{m})^n\) (croak.preprocess.third_order_scale()).
croak.marginal_checks.auto_third_order_exponent() picks the exponent whose
corrected-marginal centroid lands on the predicted centroid — a unique root,
because the tilt shifts the centroid monotonically in \(n\):
n = mc.auto_third_order_exponent(
lam, marg, lam_spec, Ilam_spec, "pg", window=(210e-9, 1000e-9)
)
corrected = trace * croak.preprocess.third_order_scale(lam, n)[:, None]
This fits one empirical response exponent; it does not correct delay-dependent collection effects.
Through an SHG crystal#
In a crystal of tens of µm the phase matching filters the SHG marginal strongly,
so the thin-medium \(S*S\) would flag a correct trace. Give the prediction the
crystal (croak.crystals.PhaseMatching: a
CrystalSetup and its thickness) and the carrier the
retrieval uses, and it becomes the crystal model’s own marginal
(croak.crystals.shg_marginal()):
import math
from croak.crystals import CrystalSetup, PhaseMatching, builtin_crystal
from croak.geometry import TwoBeamGeometry
crystal = CrystalSetup(
builtin_crystal("BBO"),
math.radians(29.2),
phase_match_wavelength=800e-9,
geometry=TwoBeamGeometry(beam_separation=5e-3, focal_length=0.2),
polarization="parallel",
)
pm = PhaseMatching(crystal, thickness=50e-6)
pred = mc.predicted_marginal(omega, S, "shg", crystal=pm, omega0=omega0)
pred.centroid, pred.rms_width # of the crystal's marginal, still hard checks
The centroid and width are no longer \(2\bar\omega_S\) and \(\sqrt2\,\sigma_S\) but
those of the computed marginal; for the crystal model they are as exact as the
thin-medium ones. The omega0 is the retrieval grid’s carrier
(td.omega0_pulse; the middle of the retrieval band), at which an explicit tilt is
refracted and the path and delay drift are taken.
The marginal correction can target the same prediction. Load the trace with the crystal it was measured through:
td = croak.preprocess.load_and_clean(
trace, lam, delays, "shg", lam_min=600e-9, lam_max=1100e-9,
lam_spec=lam_spec, Ilam_spec=Ilam_spec,
marginal_correct=True, marginal_crystal=pm,
)
Each frequency row is then rescaled onto the crystal’s marginal, which removes
what the model leaves out (the spectrometer’s and detector’s response, the
dispersion of the nonlinear coefficient, the beams’ overlap) and keeps the phase
matching for the retrieval’s crystal model to describe. td.marginal_crystal
records the crystal, and retrieve_from_tracedata() refuses to
retrieve a corrected trace through any other medium: a thin-medium correction
divides out the phase matching, which a crystal model would apply again, and a
crystal correction leaves in a filter a thin model cannot reproduce. A session
uses the retrieval’s crystal for the correction
(croak.session.pipeline.correction_crystal()), so the two cannot disagree.
The correction relies on the same assumption as the check: the delay scan holds the whole trace. A crystal’s walk-off lengthens the trace in delay, so check that the scan covers its tails.
In the GUI#
All of the above is interactive on the GUI’s Check the marginal step, the
second step of the Data stage, which sits between the data loaders and Prepare
for measured, simulated and synthetic sessions. It overlays the predicted marginal on the measured
one, marks the predicted vs measured centroid, reports the width-bracket check,
and exposes the trust region, a log/linear toggle and the (λ/µm)^exp correction
with an Auto (centroid-matching) button. The SHG marginal correction also
lives here: it rescales the trace’s frequency rows onto the predicted SHG
marginal (apply_marginal_correction()): the
autoconvolution, or the crystal’s marginal when the crystal is modelled (its
settings are on the Data stage, before this step). It is enabled only for an SHG
trace with an independent spectrum, and previews the snap
onto the prediction live (the correction itself is applied during preprocessing,
via load_and_clean()’s marginal_correct). See the
GUI guide.